Untitled Document
  ±Þ¼ö°¡¾Ð ºÎ½ºÅÍÆßÇÁ

DBS-I ÀιöÅÍ ÆdzÚÀåÂøÇü

DBS-MI ÀιöÅÍ ¸ðÅͳ»ÀåÇü
DBS-S ´ë¼öÁ¦¾îÇü

2BIÇü 2ÆßÇÁ ÀιöÅ͸ðÅͳ»Àå
2BSÇü 2ÆßÇÁ ´ë¼öÁ¦¾î
¼±Á¤µµ ¹× ¿ÜÇüµµ
Çì´õ ¹× ÅÊÅ©¼±Á¤Ç¥
 
  1ÆßÇÁ ¼ÒÇü°¡¾ÐºÎ½ºÅÍÆßÇÁ
1BI ÀιöÅÍ ³»ÀåÇü
1BS ÀÚµ¿°¡¾Ð½Ä ÆßÇÁ
  ±Þ¼ö °¡¾Ð ÆßÇÁ
DVTÇü ÀÔÇü´Ù´ÜÅͺóÆßÇÁ
DMVÇü ´Ù´Üº¼·çÆ®ÆßÇÁ
DMPÇü ´Ù´ÜÅͺóÆßÇÁ
DDVÇü ¾çÈíÀÔº¼·çÆ®ÆßÇÁ
 
  ¼ÒÇü °¡¾Ð ÆßÇÁ
OCSÇü ½ºÆ¿½ºÅÙ ¿ø½É ÆßÇÁ
MCX,JTX,DHIÇü ¿ø½É°¡¾ÐÆßÇÁ
PCFÇü Çöó½ºÆ½ ¿ø½ÉÆßÇÁ
1BIÇü 1ÆßÇÁ ÀιöÅÍ ³»ÀåÇü
1BSÇü 1ÆßÇÁÀÚµ¿°¡¾ÐÆßÇÁ
  ¼øȯ¿ë ¹× ÀϹݾç¼ö°¡¾Ð ÆßÇÁ
DSVÇüÆíÈíÀÔ ¹ú·çÆ®ÆßÇÁ
DSV-HÇü Á߿¼ö¼øȯÆßÇÁ
DLPÇü,DLP-IÇü,ÀÎ-¶óÀÎÆßÇÁ
DLP-LÇü ±ÞÅÁ¼øȯ¶óÀÎÆßÇÁ
DLP-VÇü º§Æ®Çü±ÞÅÁ¶óÀÎÆßÇÁ
DDVÇü ¾çÈíÀÔ¹ú·çÆ®ÆßÇÁ
DMC4PÇü Á÷°á¹ú·çÆ®ÆßÇÁ
DMC2PÇü 2±ØÁ÷°áº¼·çÆ®ÆßÇÁ
OCSÇü ½ºÆ¿½ºÅÙ¿ø½ÉÆßÇÁ
  ¼Ò¹æ¿ë ÆßÇÁ
DMVÇü ´Ù´Ü¹ú·çÆ®ÆßÇÁ
DMTÇü ´Ù´ÜÅͺóÆßÇÁ
DVTÇü ÀÔÇü´Ù´ÜÅͺóÆßÇÁ
DWPÇü ¿þ½ºÄÚÃæ¾ÐÆßÇÁ
DDVÇü ¾çÈíÀÔº¼·çÆ®ÆßÇÁ
  º¸ÀÏ·¯ º¸±Þ¼ö ÆßÇÁ
DMC2PÇü 2±ØÁ÷°á¹ú·çÆ®ÆßÇÁ
DVTÇü ÀÔÇü´Ù´ÜÅͺóÆßÇÁ
DMVÇü ´Ù´Ü¹ú·çÆ®ÆßÇÁ
DMTÇü ´Ù´ÜÅͺóÆßÇÁ
DWPÇü ¿þ½ºÄÚÆßÇÁ
FJÇü ÈÞÁ¬Æ®
  ÀÀÃà ¼öȸ¼ö ÆßÇÁ
DCP Äܵ§¼¼À̼ÇÆßÇÁ
  ¹è¼ö,¿À¼ö,Àâ¼ö¿ë ÆßÇÁ
DWEÇü¼öÁß¹è¼öÆßÇÁ
DWE-CÇü,DWE-VÇü ¼öÁß¿À¼öÆßÇÁ
DVSÇü ÀÔÇü¹è¼öÆßÇÁ
DSPÇü ÀÚÈí½ÄÆßÇÁ
DVPÇü º¼ÅؽºÆßÇÁ
  û¼ö¿ë ¼öÁßÆßÇÁ
DNX/BIOÇü ½ºÅÙ¼öÁß¹è¼öÆßÇÁ
SPVÇü Çöó½ºÆ½ ¼öÁß¹è¼öÆßÇÁ
  Áø°øÆßÇÁ
DYVÇü ¼öºÀ½ÄÁø°øÆßÇÁ/ÆÐÅ·¿ë
DYV-HÇü ¼öºÀ½ÄÁø°øÆßÇÁ/M/S¿ë
  ¾Ð·ÂÅÊÅ©
AFÇü ¾Ð·ÂÅÊÅ©
  Çؼö,³»»ê,È­ÇпëÆßÇÁ
½ºÅÙ·¹½º ³»»êÆßÇÁ
KNAÇü Çöó½ºÆ½¿ø½ÉÆßÇÁ
SPVÇü Çöó½ºÆ½ ¼öÁß¹è¼öÆßÇÁ
OCSÇü ½ºÆ¿½ºÅÙ¿ø½ÉÆßÇÁ
  ¼Ò¹æ ¿£ÁøÆßÇÁ
¼Ò¹æ¿£ÁøÆßÇÁ
 

¢Â º¸ÀÏ·¯ ±Þ¼ö¿ëÀ¸·Î ÃÖÀû, ¼ÒÈ­Àü Ãæ¾ÐÆßÇÁ
¤ý°íÃþ »ó¼öµµ¿ë
¤ý°£ÀÌ »ó¼öµµ¿ë
¤ý Most Suitable for boiler water supply
¤ý pressure compensation for fire hydrants
¤ý Water works for high-rise buildings
¤ýº¸ÀÏ·¯ »ç¿ë Åæ¼ö¿¡ µû¶ó¼­ ȸÀüÂ÷(BC)¸¦ ¼³°èÁ¦ÀÛÇÕ´Ï´Ù.
¤ýº¸ÀÏ·¯ »ó¿ë¾Ð·Â (kg/cm2)¿¡ µû¶ó¼­ Motor ¸¶·Â¼ö¸¦ °áÁ¤ÇÕ´Ï´Ù.
¤ý¿Âµµ 90~95OC±îÁö ±Þ¼ö°¡ µË´Ï´Ù.(ÈÞÁ¬Æ® ¹ëºê¼³Ä¡¿¡ ÇÑÇؼ­)
¤ý¼ÒÇüÀ̹ǷΠ¼³Ä¡, Á¡°Ë, º¸¼ö°¡ ¿ëÀÌÇϸç, ´Ù´ÜÆßÇÁ¿¡ ºñÇÏ¿© °íÀåÈ®·üÀÌ °ÅÀÇ ¾ø½À´Ï´Ù.
¤ý¼Ò¿ä¸¶·ÂÀÌ Å¸ÆßÇÁ¿¡ ºñÇØ 1/2 Àý°¨µÇ¹Ç·Î ¿¬·áºñ°¡ 50%Á¤µµ Àý°¨µË´Ï´Ù.
 
¤ýImpellers are designed and manufactured in accordance to the tonnage of the boiler
¤ýThe hors power is determined according to the common pressure(kg/cm) of boiler
¤ýWater up 90~95OC is supplied in case Fu-jet value in installed only)
¤ýSince it is small in size, the installation, checking and repair is easy and less trouble, compared to multi-atagepumps
¤ý The required horse power is saved to the half and energy cost is also cut to about 50%
 
Çü½Ä (Model) DWP
ÅäÃâ·® (Capacity) Max. 0.3 m3/min
Àü¾çÁ¤ (Head) Max. 175 m
¿Âµµ (Temperature) Max. 95OC
ȸÀü¼ö (Revolution) 1450rpm, 1750 rpm
±¸°æ (Bore) 25 ~ 80 mm
(ÅäÃⱸ°æ±âÁØ)
ȸÀü¹æÇâ (Rotation) ±¸µ¿Ãø¿¡¼­ º¸¾Æ ½Ã°è¹æÇâ
Clockwise viewed from coupling end


ÈíÀÔ±¸·ÎºÎÅÍ Âù³Ú¿¡ Èê·¯µé¾î¿À´Â ¾×ü´Â ȸÀüÂ÷ÀÇ ¹ÙÅ°µå¿¡¼­ Áï½Ã °¡¼ÓµÇ°í, Àü´Ü·Â¿¡ ÀÇÇÏ¿© ±×¸²1ÀÇ Âù³ÚÀ» ÅëÇؼ­ ¼ÛÃâµË´Ï´Ù. ȸÀüÂ÷ÀÇ ¹öÄÏ(Impeller Bucket) ³»¿¡¼­ÀÇ ¾×üÀÇ È帧Àº ±×¸²2 ¿¡ ±×·ÁÁ® ÀÖ½À´Ï´Ù. ÀÌ °úÁ¤Àº ¾×ü°¡ ¼ÛÃâµÉ ¶§±îÁö ¿¡³ÊÁö°¡ °¢ ½ÎÀÌŬ ¸¶´Ù Áõ°¡µÇ¸ç, ¸î¹øÀÌ°í µÇÇ®ÀÌ µÇ¸é¼­ ¹Ýº¹µË´Ï´Ù.
 
¢Â ¼±Á¤µµ
 
 
¢Â ¿ÜÇüµµ
 
 
¢Â Á¶¸³±¸Á¶µµ
 
±¸ºÐ
ÄÉÀÌ½Ì (Casing)
ÀÓÆç·¯ (Impeller)
ÁÖÃà (Shaft)
ÁÖÃà (Shaft)
±âº»ÀçÁú (Standard)
GC200
BC6
SM45C
Gland Packing
¿É¼ÇÀçÁú (Option)
SSC13, SSC14
SSC13, SSC14
STS304, STS316
Mechanical Seal
 
 


Á¦¸ñ ¾øÀ½